Complimentary shippingWR2500Through Sept 30
Complimentary shipping · Through Sept 30
For architects
A factory-charged through-the-wall cabinet. The drawing set needs a non-loadbearing interior wall, a 15 5/8 in by 9 1/4 in opening, a wall between 5.5 and 14 in, a dedicated 115V / 60Hz / 15A circuit, and a sloped condensate drain.
Through-the-wall wine cellar cooling
Reviewed · September 3, 2026
The WR2500 is a factory-charged through-the-wall wine cellar cooling unit. Through-the-wall means the heat rejects into the adjoining room. Plan that room. Dedicated 15A circuit. No shared lighting, no extension cord, no switched outlet. Slope the condensate line. Long runs, rises, or loops need a pump. Cut sheets live in Documentation. There is no DWG pack on this site.
On the job
Electrical and drain
From the cut sheet
Cutout
Cutout 15 5/8 x 9 1/4 in (397 x 235 mm), typically above the door. Walls 5.5 to 14 in (140 to 355 mm).
Clearances
12 in (305 mm) clear on the cold side, 18 in (457 mm) on the warm side, both unobstructed.
Drain
3/8 in ID line with continuous downward slope. Runs over 5 ft, rises, or loops need a pump.
Specification sequence
For cellars that have to look finished with a through-the-wall unit in the wall. The drawing set carries the envelope, the load, the opening, the drain, and the electrical. There is no remote compressor to hide in another room.
Millwork can frame the face if free area and published clearances stay open. Leave a path to remove the unit without dismantling finished cabinetry. 2-year parts warranty.
Specification paragraph
Provide a factory-charged, through-the-wall wine cellar cooling unit, Wine-R WR2500, using R-290 refrigerant; a dedicated 115V/60Hz/15A circuit with no extension cord and no switched outlet; a non-loadbearing interior wall 5.5 to 14 in thick with a 15 5/8 in by 9 1/4 in opening, typically above the door; 12 in cold-side and 18 in warm-side clearance; a sloped 3/8 in ID condensate drain with continuous fall; and an envelope built to R-20 with a sealed vapor barrier. Double-pane sealed glass only. Capacity: 2,337 BTU/h nominal, up to 700 ft³ (19.8 m³) with glass walls or 900 ft³ (25.5 m³) fully enclosed when the envelope meets specification. 2-year parts warranty for the original buyer, registration within 30 days.
Specifications
Conditions: R-20 envelope, sealed vapor barrier, double-pane sealed glass. Warm-side ambient 50 to 90°F (10 to 32°C).
Capacity
Opening and wall
Services and coverage
WR2500: R-290 refrigerant, factory-charged, 3/8 in ID condensate drain, dedicated 115V/60Hz/15A circuit. Capacity only with an envelope built to specification. Source: WR2500 user guide.
Common questions
Back to Wine-R Pro. Related: BTU calculator, Documentation, Compatibility check, Vapor barriers.
Wine-R Pro documents support design, bid, and specification work. They are not a site assessment, an engineering approval, or an installation certification. Final sizing, opening, drainage, and electrical are confirmed on site by the responsible trades. Wine-R does not install and does not certify installers. The WR2500 is sold under Wine-R’s Terms of Sale and Limited Warranty.
The WR2500 is sold under Wine-R’s Terms of Sale and Limited Warranty. Wine-R’s warranty covers unit parts for two years from the original purchase date.
Warranty coverage is voided by, among other conditions:
Pre-validation by Wine-R confirms unit fitment against declared measurements only. The owner or installer is responsible for envelope construction, wall structural assessment, electrical compliance, drainage routing, and ongoing operating conditions. Wine-R does not warrant against water damage, mold, finish degradation, or property loss caused by installation, drainage configuration, site conditions, or operating environment.